A heat pump covered in ice is a problem when the ice is thicker than about 1/4 inch or is still there after the unit defrosts. A thin coat of frost on the outdoor unit that comes and goes on a cold Central Texas morning is normal. Carrier draws the line at 1/4 inch, and points to restricted airflow, low refrigerant or a defrost fault when ice goes past it. Here is how to tell which one you are looking at, and what to leave alone.
Is it normal for a heat pump to have ice on it?
Light frost on a heat pump's outdoor coil is normal in winter, because the coil is pulling heat out of cold air and moisture freezes to it. A coating of solid ice is not normal. Carrier's troubleshooting guide says a little frost is expected, while a coating of ice blocks airflow and greatly reduces how well the coil works.
| What you see outside | What it usually means |
|---|---|
| White frost under 1/4 inch that clears | Normal |
| Steam or fog for a few minutes | Normal defrost |
| Ice on the grille during freezing rain | Normal for that weather |
| Ice over 1/4 inch on the coil or copper tubing | Needs service |
| Ice still there after a defrost cycle | Needs service |
| Water or ice collecting under the unit | Drainage or leveling problem |
What does a normal defrost cycle look like?
During a normal defrost cycle the outdoor unit may steam, whoosh and drip for several minutes, then go back to heating. Carrier's manual for the 25VNA8 heat pump describes a "whoosh" at the start and end of defrost, and says steam or fog rising from the unit is normal. Carrier puts a typical cycle at about 5 to 10 minutes. A homeowner guide on the Department of Energy's building science site gives 5 to 15 minutes.
The unit does not need a freeze to make frost. Carrier's owner's manual for its 50NT heat pump says moisture may begin to freeze on the coil once the outdoor temperature drops below 45°F. On that model defrost is set to a 60-minute interval, and it starts only if there is enough ice to interfere with heating. Intervals differ by model, so your own manual has the final word.
The air inside can change too. Carrier notes that auxiliary heat may run during defrost so the vents do not blow cold, which is one of the normal reasons a thermostat shows AUX. We cover the others in heat pump thermostat settings for winter.
How often should this happen in Central Texas?
Frost is an ordinary winter sight on a Central Texas heat pump. Heavy ice should be rare. The National Weather Service puts Austin's normal January lows in the low 40s, which is already inside Carrier's frost range on a typical night. Actual sub-freezing temperatures show up on about 12 days a year at Camp Mabry and 33 days at the Austin airport, which sits in a low area that runs colder.
Ice storms are the exception. The Weather Service says freezing rain, sleet or snow significant enough to disrupt travel reaches the Austin area about once every two years. Carrier's 50NT manual says ice on the unit's grille in that weather is normal, does not affect how the unit works and clears within a few days. Carrier also says not to try to remove it. Ice on the grille is different from ice packed into the coil behind it.
What makes a heat pump freeze over?
A heat pump freezes over when it cannot melt frost as fast as frost forms, or when outside water keeps landing on it. Carrier's troubleshooting guide names four causes:
- Low refrigerant. The system cannot produce enough heat to melt the ice. Testing and charging it is a technician's job.
- A failed defrost timer. The unit does not defrost when it should, so each layer of frost freezes onto the last.
- A bad outdoor fan motor. With little or no air moving through the coil, the coil ices up.
- Water dripping onto the unit. Carrier says defrost may not keep up with a severe freeze-over, and to find the source of the water, such as a leaky gutter, and repair the leak.
The water source is the one homeowners miss, because the heat pump itself is fine. If the ice is heaviest on the side under the roof edge, look up before you blame the equipment. A dripping seam above the unit needs a gutter repair that seals leaking joints, and Urtiz Roofing does that work across Liberty Hill and the Austin area. Until the drip stops, the ice will likely come back.
Drainage is the other one. Carrier's manual says that if the support base settles and the unit is no longer level, it should be re-leveled promptly so it drains, and that water or ice collecting underneath needs to be drained away.
What should I do if my heat pump is frozen solid?
Do not chip the ice, and do not open the unit. Carrier says to never try to chip ice from the coil. What you can safely do from outside the cabinet is short:
- Clear the area. Move leaves and debris away from the sides and top. Carrier's general guideline is 24 inches of clear space, and the 25VNA8 manual sets a 12 inch minimum from tall grass, vines and shrubs.
- Take off any cover. Carrier says not to cover the outdoor unit, and the homeowner guide says the same for winter.
- Check the indoor filter. Replace it if it is loaded.
- Watch the ground. Meltwater that pools on a walkway can refreeze.
- Use emergency heat if the outdoor unit has stopped working. Carrier recommends using it sparingly, because electric resistance heat can significantly increase the bill.
When should I call for heat pump repair?
Call for heat pump repair when ice is still on the coil after a defrost cycle, when it is thicker than 1/4 inch, when the unit defrosts unusually often, or when the house will not warm up. Carrier recommends a professional inspection if heavy ice remains or defrost runs too often, and the homeowner guide says the same for a unit stuck in defrost.
Refrigerant charge, the defrost control and the fan motor are work for a licensed technician. A maintenance visit before the cold sets in is the better time to find them. A Department of Energy heat pump maintenance guide lists verifying that the defrost timer works, and a homeowner has no easy way to check that from the yard.
Getting it looked at
Comfort Pros is a Carrier factory authorized dealer serving Leander, Cedar Park, Georgetown, Liberty Hill, Lago Vista and Jonestown, licensed under TACL# TACLB116912E. If your heat pump is iced over and staying that way, call us. It helps to take a photo of where the ice is heaviest before it melts, because that often says whether the problem is in the unit or above it.