Yes, an older air conditioner can still be repaired after the R-410A phase-down. The EPA's rules restrict which refrigerants new equipment can use. The EPA says its rule does not restrict the continued use of any existing system, and that a system may be serviced and repaired throughout its useful life. For a home in Leander or Cedar Park with a system that runs on R-22 or R-410A, the practical change is that a leak should be found and fixed instead of topped off.
Which refrigerant does my air conditioner use?
A home air conditioner uses one of three refrigerants, depending mostly on when it was made, and the nameplate on the outdoor unit says which.
| Refrigerant | Where it stands | What it means for repairs |
|---|---|---|
| R-22 (HCFC-22, often called Freon) | No new R-22 has been made or imported into the United States since January 1, 2020 | The system can stay in use. Reclaimed R-22 is still available for service |
| R-410A (sold as Puron) | The most common refrigerant in systems that replaced R-22, now being phased down | The system can be serviced and repaired throughout its useful life |
| R-454B (sold as Puron Advance) | The lower-impact refrigerant in new Carrier equipment | Only for systems designed for it |
The dates and rules in the first two rows come from the EPA's homeowner questions on the refrigerant phaseout. The third row comes from Carrier.
Is R-410A being phased out?
R-410A is being phased down, which is a shrinking supply and not a ban on using it. The American Innovation and Manufacturing Act, enacted on December 27, 2020, requires the phasedown of hydrofluorocarbons by 85 percent by 2036, and the EPA describes R-410A as a blend of two hydrofluorocarbons. The EPA's phasedown schedule began with a 10% reduction in 2022 and stepped down again in 2024 to 60% of baseline levels.
New equipment changed on January 1, 2025. Starting on that date, the EPA's Technology Transitions rule restricts higher-impact refrigerants in new residential air conditioning and heat pump equipment, with a global warming potential limit of 700. Carrier lists R-410A at 2,088 and its R-454B replacement at 466, which is why new systems no longer ship with R-410A.
Can my R-410A or R-22 system still be repaired?
Yes. The EPA states that its rule does not restrict the continued use of any existing products or systems, that a system may be serviced and repaired throughout its useful life, and that components needed to repair existing equipment may continue to be manufactured, imported and sold.
The same holds for R-22. The EPA says it does not require homeowners to replace their existing equipment and that people can continue to use air conditioning equipment that uses HCFC-22. Supply now comes from recovered refrigerant: the EPA reports that reclaimers reclaimed more than 140 million pounds of HCFC-22 from 2000 to 2018, and it expects reclaimed and previously produced R-22 to meet the needs of existing systems well beyond the phaseout date.
Can a newer refrigerant go into my older system?
No. The EPA says there are no drop-in replacements for HCFC-22 and that alternative refrigerants will not work well without changes to system components. Carrier says the same about the newer step: R-454B cannot be used as a direct replacement for R-410A in an existing system, because a system must be designed and approved for the refrigerant it uses.
Carrier classifies R-454B as mildly flammable and builds its R-454B systems with a detection and dissipation system that an R-410A unit does not have. An offer to convert an older system to a new refrigerant is a reason to ask more questions, not a shortcut.
What should I ask for when my system is low on refrigerant?
Ask the technician to find and repair the leak. The EPA advises homeowners to request that service technicians locate and repair leaks instead of topping off leaking systems, which it says minimizes future service calls and repair costs and improves performance. Refrigerant runs in a closed loop, so a system that is low has a leak somewhere.
Ask about certification too. EPA regulations under Section 608 of the Clean Air Act require that technicians who service or repair equipment that could release refrigerant be certified. Refrigerant is not a homeowner job, and it is the reason AC repair on a low system starts with a leak search and not a recharge.
When does a refrigerant leak point toward replacement?
A single leak that can be found and repaired is a repair. The question changes when leaks keep coming back on a system that is already old, and the EPA's advice to repair leaks instead of refilling them is the reason a technician should show you where the leak is before recommending anything. Our guide to repairing or replacing a 12-year-old AC covers how to weigh that decision.
Getting a straight answer on your system
Comfort Pros is a Carrier factory authorized dealer serving Leander, Cedar Park, Georgetown and Liberty Hill, licensed under TACL# TACLB116912E. If your system is low on refrigerant or you have been told it cannot be serviced, call us. We will find the leak, tell you which refrigerant the system uses and what the repair involves, and talk through AC replacement only if the system calls for it.